Terminals | Quantity | Specification |
Digital input | 4 channels | Programmable multifunctional terminal Maximum input frequency: 1kHz Compatible with NPN and PNP inputs |
High speed pulse input | 2 channels | Maximum input frequency: 50KHz Compatible with NPN and PNP inputs It supports orthogonal encoder input and has speed measurement function |
Analog input | 2 channels | 0~10V,0~20mA, -10V~+10V |
Digital output | 1 channel | Max. output frequentcy:1KHz |
High speed pulse output | 1 channel | Max. output frequency:50KHz |
Analog output | 2 channels | 0~10V,0~20mA |
Relay output | 2 channels | 3A/250VAC, 1A/30VDC, NO+NC |
Experiment type | Experiment name | Classification |
Mechanical reliability experiments |
Package experiments | Package compression experiments |
Package resonance imaging and storage test | ||
Package random vibration test | ||
Package dropping test | ||
Package rolling test | ||
Package dumping test | ||
Package inclined impact test | ||
Impact test | Half-sine wave impulse test(non-working state) | |
Trapezoidal wave impulse test (non-working state) | ||
Vibration test | Sinusoidal vibration test (working state) | |
Random vibration test (working and non-working state) | ||
Climatic environmental reliability test |
Temperature experiment | Low temperature storage test |
High temperature storage test | ||
Low temperature experiments | ||
High temperature experiments | ||
Temperature gradient experiments | ||
Temperature impact test | ||
Thermal test | Constant thermal test | |
Alternation thermal test | ||
Salt spray test | Constant salt spray test | |
Alternation salt spray test | ||
Low air pressure test | Low Air Pressure Test | |
Low temperature and low pressure test | ||
High temperature and low pressure test |
Model no. | Output power (kW) | Input current(A) | Output current(A) | Carrier frequency(kHz) | Remark |
FD300-0R7G/1R5P-4 | 0.75 | 3.4 | 2.5 | 1~15(8/4) | |
FD300-1R5G/2R2P-4 | 1.5 | 5.0 | 4.2 | 1~15(8/4) | |
FD300-2R2G/003P-4 | 2.2 | 5.8 | 5.5 | 1~15(8/4) | |
FD300-004G/5R5P-4 | 4 | 13.5 | 9.5 | 1~15(8/4) | |
FD300-5R5G/7R5P-4 | 5.5 | 17 | 14 | 1~15(8/4) | |
FD300-7R5G/011P-4 | 7.5 | 25 | 18.5 | 1~15(8/4) | |
FD300-011G/015P-4 | 11 | 32 | 25 | 1~15(8/4) | |
FD300-015G/018P-4 | 15 | 40 | 32 | 1~15(4/2) | |
FD300-018G/022P-4 | 18 | 47 | 38 | 1~15(4/2) | |
FD300-022G/030P-4 | 22 | 51 | 45 | 1~15(4/2) | |
FD300-030G/037P-4 | 30 | 57 | 60 | 1~15(4/2) | Optional DC reactor |
FD300-037G/045P-4 | 37 | 69 | 75 | 1~15(4/2) | |
FD300-045G/055P-4 | 45 | 89 | 91 | 1~15(4/2) | |
FD300-055G/075P-4 | 55 | 110 | 115 | 1~15(4/2) | |
FD300-075G/090P-4 | 075 | 140 | 150 | 1~15(2/1.5) | |
FD300-090G/110P-4 | 90 | 165 | 180 | 1~15(2/1.5) | |
FD300-110G/132P-4 | 110 | 200 | 215 | 1~15(2/1.5) | |
FD300-132G/160P-4 | 132 | 250 | 260 | 1~15(2/1.5) | |
FD300-160G/185P-4 | 160 | 290 | 315 | 1~15(2/1.5) | |
FD300-185G/200P-4 | 185 | 320 | 340 | 1~15(2/1.5) | Optional DC reactor |
FD300-200G/220P-4 | 200 | 365 | 380 | 1~15(2/1.5) | |
FD300-220G/250P-4 | 220 | 410 | 425 | 1~15(2/1.5) | |
FD300-250G/280P-4 | 250 | 445 | 470 | 1~15(2/1.5) | |
FD300-280G/315P-4 | 280 | 500 | 530 | 1~15(2/1.5) | |
FD300-315G/355P-4 | 315 | 580 | 600 | 1~15(2/1.5) | |
FD300-355G/400P-4 | 355 | 620 | 650 | 1~15(2/1.5) | Standard DC reactor |
FD300-400G/450P-4 | 400 | 690 | 725 | 1~15(2/1.5) | |
FD300-450G/500P-4 | 450 | 785 | 820 | 1~15(2/1.5) | |
FD300-500G/630P-4 | 500 | 825 | 860 | 1~15(2/1.5) | |
FD300-630G/710P-4 | 630 | 1050 | 1100 | 1~15(2/1.5) | |
Function | Specification | |
Power input | Input voltage (V) | AC 3PH 380V(-15%)~440V(+10%) Rated voltage: 380V |
Input current (A) | Refer to “Rated specifications)” | |
Input frequency (Hz) | 50Hz or 60Hz Allowed range: 47~63Hz |
|
Power output | Output voltage (V) | 0~input voltage |
Output current (A) | Refer to “Rated specifications” | |
Output power (kW) | Refer to “Rated specifications” | |
Output frequency (Hz) | 0~600Hz(export: 0~400Hz) | |
Technical control feature |
Control mode | Space voltage vector control(SVPWM) Sensorless vector control (SVC) Vector control with sensor feedback (FVC) |
Motor type | Asynchronous motor (AM) and permanent magnetic synchronous motor (SM) |
|
Adjustable-speed ratio | For AM1: 1:200 (SVC); for SM1, 1:20 (SVC); 1:1000 (FVC) |
|
Speed control accuracy | ± 0.2% (SVC); ± 0.02% (FVC) | |
Speed fluctuation | ± 0.3% (SVC) | |
Torque response | < 20ms (SVC); < 10ms (FVC) | |
Torque control accuracy | 10% (SVC); 5% (FVC) | |
Starting torque | For AMs: 0.25Hz/150% (SVC) For SMs: 2.5Hz/150% (SVC) 0Hz/200% (FVC) |
|
Overload capability | G type 150% of rated current: 1 minute 180% of rated current: 10 seconds 200% of rated current: 1 second P type 120% of rated current: 1 minute 150% of rated current: 3 seconds 160% of rated current: 1 second |
|
Running control feature | Frequency setting method | Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting, PID setting, Modbus communication setting, PROFIBUS communication setting. Switch between the combination and single setting channel. |
Auto-adjustment of the voltage | Keep constant voltage automatically when the grid voltage transients | |
Fault protection | Provide more than 30 fault protection functions: overcurrent, overvoltage, undervoltage, overheating, phase loss and overload, etc. |
|
Restart after rotating speed tracking | Smooth starting of the rotating motor | |
Peripheral interface | Terminal analog input resolution | ≤ 20mV |
Terminal switch input resolution | ≤ 2ms | |
Analog input | 1(AI1) 0–10V/0–20mA and 1 (AI2) -10–10V | |
Analog output | 2 (AO1, AO2) 0–10V /0–20mA | |
Digital input | 4 common inputs, the Max. frequency: 1kHz, internal impedance: 3.3kΩ; 2 high speed input, the Max. frequency: 100kHz |
|
Digital output | 1 high speed pulse output, the Max. frequency: 100kHz; 1 Y terminal open collector output |
|
Relay output | 2 programmable relay outputs T1A NO, T1B NC, T1C common terminal T2A NO, T2B NC, T2C common terminal Contactor capability: 3A/AC250V,1A/DC30V |
|
Communication | 1 channel RS485 | |
Extended interfaces | 5.5kW and below: two extended interfaces(SLOT1, SLOT2) 7.5kW and above: three extended interfaces: SLOT1, SLOT2, and SLOT3 Supporting PG cards, programmable expansion cards, communication cards, I/O cards and so on |
|
Others | Mountable method | Wall mounting, flange mounting, floor mounting Above 45kW, need optional kit for flange mounting Above 200kW need optional basement for floor mounting |
Temperature of the running environment | -10~50℃, derate above 40℃ | |
MTBF | 2 years (30℃ ambient temperature) | |
Protective degree | 0.4~185kW IP20 200~630kW IP00; Optional IP20 |
|
Pollution degree | Degree 2 | |
Altitude | Below 1000m; If it exceeds 1000m, the derating shall be reduced by 1% every 100m, and the maximum altitude shall not exceed 5000m. | |
Cooling | Air-cooling | |
Braking unit | 37kW and below built-in DBU; 45~110kW optional built-in DBU | |
EMC filter | Built-in C3 filter: meet the degree requirement of IEC61800-3 C3 Optional filter: meet the degree requirement of IEC61800-3 C2 |
Size Chassis code |
Model no. | Installation | Dimension | Hole size | ||||||
A1 | A2 | B | H | H1 | W | W1 | D | |||
T1 | FD300-0R7G/1R5P-4 | 114 | 180 | 190 | / | 125 | / | 185 | φ5 | |
FD300-1R5G/2R2P-4 | ||||||||||
FD300-2R2G/003P-4 | ||||||||||
FD300-004G/5R5P-4 | ||||||||||
FD300-5R5G/7R5P-4 | ||||||||||
T2 | FD300-7R5G/011P-4 | 147 | 298 | 310 | / | 160 | / | 208 | φ6 | |
FD300-011G/015P-4 | ||||||||||
FD300-015G/018P-4 | ||||||||||
T3 | FD300-018G/022P-4 | 187 | 333 | 345 | / | 200 | / | 208 | φ6 | |
FD300-022G/030P-4 | ||||||||||
T4 | FD300-030G/037P-4 | 227 | 378 | 390 | / | 240 | / | 222 | φ6 | |
FD300-037G/045P-4 | ||||||||||
T5 | FD300-045G/055P-4 | 180 | 540 | 515 | 555 | 285 | / | 252 | φ9 | |
FD300-055G/075P-4 | ||||||||||
FD300-075G/090P-4 | ||||||||||
T6 | FD300-090G/110P-4 | 260 | 535 | 511 | 555 | 340 | / | 336 | φ11 | |
FD300-110G/132P-4 | ||||||||||
T7 | FD300-132G/160P-4 | 260 | 800 | 775 | 825 | 340 | / | 400 | φ11 | |
FD300-160G/185P-4 | ||||||||||
FD300-185G/200P-4 | ||||||||||
Without optional parts | ||||||||||
T8 | FD300-200G/220P-4 | 260 | 170 | 980 | 1080 | 1133 | 340 | / | 475 | φ11 |
FD300-220G/250P-4 | ||||||||||
T9 | FD300-250G/280P-4 | 260 | 170 | 1149 | 1260 | 1313 | 340 | / | 550 | φ11 |
FD300-280G/315P-4 | ||||||||||
FD300-315G/355P-4 | ||||||||||
T10 | FD300-355G/400P-4 | 260 | 170 | 1259 | 1370 | 1423 | 340 | / | 550 | φ11 |
FD300-400G/450P-4 | ||||||||||
FD300-450G/500P-4 | ||||||||||
With optional parts | ||||||||||
T8 | FD300-200G/220P-4 | 260 | 170 | 980 | 1440 | 1493 | 340 | 422 | 475 | φ11 |
FD300-220G/250P-4 | ||||||||||
T9 | FD300-250G/280P-4 | 260 | 170 | 1149 | 1591 | 1644 | 340 | 478 | 550 | φ11 |
FD300-280G/315P-4 | ||||||||||
FD300-315G/355P-4 | ||||||||||
T10 | FD300-355G/400P-4 | 260 | 170 | 1259 | 1701 | 1754 | 340 | 478 | 550 | φ11 |
FD300-400G/450P-4 | ||||||||||
FD300-450G/500P-4 |
Note: 1.The max power rating of FD300 400 voltage level is 630kW 2.The input current is the actual test result when the input voltage is 380V, and for 30kW and above ratings, the input current is measured with DC reactor configured. The input current 3.The output current refers to ABB and is defined as 380V rated output current. 4.Under the allowable input voltage range, the output current shall not exceed its limit output current; The output power shall not exceed its rated output power. 5.Inverters 37kW and below built-in DBU standard. 6.Inverters 45~110kW standard without DBU(can be built-in DBU optionally with –B model) |